IntelliSensor™ Plus Multi-depth Stud Finder INSTRUCTION MANUAL

38mm

1

IntelliSensor™ Plus (77-115) The Stanley® IntelliSensor™ Plus uses electronic signals to locate the position of studs or joists through drywall and other common wall materials. Once the edge of the stud has been detected, the IntelliSensor™ Plus LED display gives visual and audio indications that allow you to easily pinpoint the stud’s edge position. A pencil line allows you to quickly note the location of the stud edges. The IntelliSensor™ Plus allows the user to locate wood and metal studs up to 1-1/2 inch Detection depth. The IntelliSensor™ Plus provides automatic calibration and heavy duty ABS construction. Depth detection selected by side button for 1/2 inch, 1 inch and 1-1/2 inch. Important: Read all instructions prior to operating the IntelliSensor™ Plus and DO NOT remove any labels from the tool.

2

ILLUSTRATION 1 Indicator Mark

LCD

38mm

Depth Detection Mode Indicator ON

ON Button / Depth Detection mode selection

ILLUSTRATION 2

A

B

C 38mm

A = Wood or metal stud depth detection up to 1/2” B = Wood or metal stud depth detection up to 1” C = Wood or metal stud depth detection up to 1-1/2”

3

Operating Instructions Prepareing for use 1.0 Battery: Open the battery door on back of unit (illustration 3) and connect a 9-volt battery (not included). Insure to align the "+" terminal of the 9-volt battery to the "+" BATTERY DOOR ILLUSTRATION3 indicator, located inside the battery compartment. Place battery door onto case and snap battery door on. Recommend to replace a new 9 volt battery when low battery. (flashing green LED).

2.0 Turning Power On The ON/MODE Button is located on the right side (illustration 1) of the hand grip.

3.0 Selecting Scanner Depth Mode 1. Depress and hold “ON” button once (1x) to select to 1/2 ” read depth detection. The 1/2”mode LED will illuminate (illustration 2). The unit will then calibrate, followed by a beep and a green LED will illuminate. 2. `Double-click’ / Depress and hold ONbutton twice (2x) to select to 1” read depth detection. The 1” mode LED will illuminate (illustration 2). The unit will then calibrate , followed by a beep and a green LED will illuminate. 3. “Triple-click”/ Depress “ON” button three times (3x) to select 1-1/2” read depth detection. The 1-1/2” mode LED will illuminate (illustration 2). The unit will then calibrate, followed by a beep and a green LED will illuminate. IMPORTANT: Unit will automatically shut- off if ON button is released following steps 1,2,3 above. 4

4.0 Calibration Calibrate the unit on wall before scanning for wood or metal stud. IMPORTANT: The unit cannot be moved before calibration is complate and before green LED & Depth LED goed on. Note:While calibrating, the IntelliSensor™ Plus must not be placed directly over a stud, dense material such as metal, wet or newly painted areas as this will prevent the unit from calibrating properly. If this is done over wood or metalstud the unit will give no indication when moved away from the area. Move to a different location and try again.

USAGE 5.0 Calibrating Following the requirements of 3.0, and 4.0, hold the IntelliSensorTM Plus flat against the surface, making firm contact. Select depth (3.0) and hold the “ON” button. The sensor will sound an audible "beep" (for 1-3 seconds) while self calibrating (Do not move while calibrating). The Buzzer will stop signifying the calibration is finished, (Only the single bottom "Green" LED will illuminate). Notes: Releasing the on-botton will turn off the sensor.

5

IMPORTANT: The unit cannot be moved before calibration is complate and before green LED & Depth LED goes on. This sensor is designed for use only on interior surfaces. For best results the depth mode selected should be based on the thickness of the surface material being scanned (Reference 3.0 and 7.0)

6

7.0 Cautions on Operating You should always use caution when nailing, cutting or drilling in walls, ceilings and floors that may contain wiring or pipes near the surface. Always remember that studs or jo