SMD Probe - 886_manual.pdf

Bk Precision 885 Synthesized In-Circuit LCR/ESR Meter w/SMD Probe Owners Manuals, User Guides, Instructional Help Documents & Operating Information - 886_manual.pdf

Report DMCA / Copyright

DOWNLOAD PDF

  • 3MB
  • 112 Pages
  • 255 x 397 pts
  • 87 Downloads
  • 284 Views

 

Citation

Instruction Manual Manual de Instrucción LCR METER Models 885 & 886 MEDIDOR LCR Modelos 885 & 886

Contents 1.

2.

INTRODUCTION..................................................... 1 1.1.

GENERAL ..................................................... 1

1.2.

IMPEDANCE PARAMETERS ..................... 3

1.3.

SPECIFICATION ........................................... 6

1.4.

ACCESSORIES ........................................... 20

OPERATION........................................................... 21 2.1. 2.2.

PHYSICAL DESCRIPTION ....................... 21 MAKING MEASUREMENT ...................... 22 2.2.1. Battery Replacement.......................... 22 2.2.2. Battery Recharging/AC operation..... 23 2.2.3. Open and Short Calibration. ............. 24 2.2.4. Display Speed .................................... 25 2.2.5. Relative Mode .................................... 25 2.2.6. Range Hold ........................................ 25 2.2.7. DC Resistance Measurement............. 26 2.2.8. AC Impedance Measurement............. 26 2.2.9. Capacitance Measurement ................ 26

2.2.10 2.3. 3.

4.

Inductance Measurement ............. 27

ACCESSORY OPERATION ....................... 28

INFRARED OPERAION........................................ 30 3.1.

COMMAND SYNTAX................................ 31

3.2.

COMMANDS............................................... 32

APLICATION ......................................................... 40 4.1.

TEST LEADS CONNECTION ................... 40

4.2.

OPEN/SHORT COMPENSATION.............. 45

5.

LIMITED ONE-YEAR WARRANTY ................... 47

6.

SAFETY PRECAUTION........................................ 52 SPANISH MANUAL .............................................. 53

1. Introduction 1.1 General The B&K Precision Models 885 & 886 Synthesized In-Circuit LCR/ESR Meter is a high accuracy hand held portable test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.5%. It is the most advanced handheld AC/DC impedance measurement instrument to date. The 885 or 886 can help engineers and students to understand the characteristic of electronics components as well as being an essential tool on any service bench. The instrument is auto or manual ranging. Test frequencies of 100Hz, 120Hz, 1KHz 10KHz or 100KHz (886) may be selected on all applicable ranges. The test voltages of 50mVrms, 0.25Vrms, 1Vrms or 1VDC (DCR only) may also be selected on all applicable ranges. The dual display feature permits simultaneous measurements. Components can be measured in the series or parallel mode as desired; the more standard method is automatically selected first but can be overridden. The Model 885 and 886 offers three useful modes for sorting components. The highly versatile Models can perform virtually all the functions of most bench type LCR bridges. With a basic accuracy of 0.2%, this economical LCR meter may be adequately substituted for a 1

more expensive LCR bridge in many situations. The meter is powered from two AA Batteries and is supplied with an AC to DC charging adapter and two AA Ni-Mh Rechargeable Batteries. The instrument has applications in electronic engineering labs, production facilities, service shops, and schools. It can be used to check ESR values of capacitors, sort values, select precision values, measure unmarked and unknown inductors, capacitors or resistors, and to measure capacitance, inductance, or resistance of cables, switches, circuit board foils, etc. The key features are as following: z Test condition: 1 Frequency : 100Hz / 120Hz / 1KHz / 10KHz / 100KHz (886) 2. Level : 1Vrms / 0.25Vrms / 50mVrms / 1VDC (DCR only) z Measurement Parameters : Z, Ls, Lp, Cs, Cp, DCR, ESR, D, Q and θ z Basic Accuracy: 0.2% z Dual Liquid Crystal Display z Fast/Slow Measurement z Auto Range or Range Hold z Infrared Interface Communication z Open/Short Calibration z Primary Parameters Display: Z : AC Impedance DCR : DC Resistance Ls : Serial Inductance 2

Lp : Parallel Inductance Cs : Serial Capacitance Cp : Parallel Capacitance z Se