Scotsman Ice Maker 600LB CM3 30inW Commercial Cubed Machine Owners Manuals, User Guides, Instructional Help Documents & Operating Information - CM500MN.pdf
Citation
CM500 Introduction To the owner or user: This service manual is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain and repair this product.
The refrigeration system uses R-502 as the refrigerant.
The CM500 is an ice machine that produces cubed ice on 2 vertical cube freezing surfaces. The cubes fall as vertical strips of cubes into the ice storage bin where they break up into individual cubes. The CM500 automatically maintains the level of ice by turning on when the ice level falls, and switches off when the bin is full.
Table of Contents Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 2
Limitations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 3
Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 4
Plumbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 5
Final Check List
page 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component Location
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 9
Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 10
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 12
Water/ Refrigeration Schematic . . . . . . . . . . . . . . . . . . . . . . . . .
page 15
Technical Characteristics
. . . . . . . . . . . . . . . . . . . . . . . . . . .
page 17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 18
Service Diagnosis
Removal and Replacement
. . . . . . . . . . . . . . . . . . . . . . . . . .
Parts lists and wiring diagrams are located in the center of this manual, printed on yellow paper. Note the warning symbol where it appears in this manual. It is an alert for important safety information on a hazard that might cause serious injury. Keep this manual for future reference.
This manual was printed on recycled paper.
December, 1992 Page 1
page 20
CM500 Specifications Information regarding Model Number, Serial Number, Ampacity and Maximum Fuse Size are located on the nameplate of the ice machine. The model number, serial number and refrigerant charge are also listed on the serial number plate just behind the front panel. If recharging, always use the charge listed on the ice machine.
Nameplate
This service manual covers every series CM500. The major changes were between "C" and "D" series when the cabinet dimensions changed, and between the "D’ and "E" series when the compressor changed.
Serial Number Plate
CM500 "E" Cabinet
"E" Series Specifications: Model Number
Dimensions W" x D" x H"
CM500AE-1E CM500WE-1E
30 x 24 x 27 30 x 24 x 27
Condenser Basic Minimum Type Electrical Circuit Ampacity Air 115/60/1 20 Water 115/60/1 20
The CM500 will stack onto a variety of ice storage bins, see sales literature for proper ice storage bin. There is an optional stainless steel panel kit, SPKCMD-1, for this machine.
December, 1992 Page 2
Maximum Fuse Size (or HACR circuit breakers) 20 20
Refrigerant Charge. R-502 32 ounces 28 ounces
CM500 For The Installer: Environmental Limitations The ice machine must be installed indoors in a controlled environment. Minimum
Maximum
Air Temp
0
50 F.
1000F.
Water Temp
400F.
1000F.
Water Pressure
20 PSI
80 PSI
Voltage
103.5
126.5
Operating the ice machine outside of the above limitations, or outdoors, is potentially damaging to the machine, and it is misuse of the machine. This may void the warranty. Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. They meet or exceed the standards of UL, NSF, and CSA. Scotsman assumes no liability or responsibility of any kind for products manufactured by Scotsman that have been altered in any way, including the use of any part and/or other components not specifically approved by Scotsman. Scotsman reserves the right to make design changes and/or improvements at any time. Specifications and design are subject to chan