RHLL-HM6024JA 15 SEER 5.0 Ton Heat Pump System - 15jpl-product-specs.pdf

Rheem Ruud/15PJL60A01/RHLL-HM6024JA 15 SEER 5.0 Ton Heat Pump System Owners Manuals, User Guides, Instructional Help Documents & Operating Information - 15jpl-product-specs.pdf

Report DMCA / Copyright

DOWNLOAD PDF

  • 559KB
  • 20 Pages
  • 612 x 792 pts (letter)
  • 63 Downloads
  • 282 Views

 

Citation

FORM NO. P11-789 REV. 1 Supersedes Form No. P11-789

Featuring New Industry Standard R-410A Refrigerant

15 SEER HEAT PUMPS Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

35" Maximum Unit Height. Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinet—louvered design protects the coil from damage. Expansion Valves with Internal Check Valve—Provides for quieter refrigerant metering. Enhanced Demand Defrost Control Factory Installed Low Pressure Control Non-Cycling Reversing Valve Hot Gas Muffler Service Valves Grille/motor mount for quiet fan operation. Easily accessible control box. Bi-Directional Filter Drier (Field Installed) Certified and rated under AHRI Standard 240. U.L listed. Optional High Pressure Control (Field-Installed: 1.5-4 ton/ Factory Installed: 5 ton only) Heat Pump Thermostat Warning Light Kit

Accessories/Options

15PJL SERIES

Low Ambient Control (Model No. RXAD-A08) Outdoor Thermostats (Model No. RXPT-A01, A02, A03 or A04) ■ Heat Pump Monitor (Model No. RXPM-B01) ■ Thermostats and Subbases (Available through the PROSTOCK® department) ■ Compressor Time Delay Control (Model No. RXMD-B01) ■ Blower Time Delay Control (Model No. RXMD-C04) RXMD-C04 is not required if the outdoor unit is matched with a Rheem Value Series furnace or air handler, or if the furnace or air handler used has a blower off time delay built-in. ■ Sound Enclosure* ■ Start Components* *Available through the PROSTOCK® department. ■ ■

“Visit www.Rheem.com for complete details.”

Applications (IN CERTAIN MATCHED SYSTEMS)

Rheem Value Series remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

Model Identification Number 15

P

J

L

18

A

01

15 SEER

P = HEAT PUMP

VOLTAGE

L = 1ST DESIGN (R-410A)

NOMINAL COOLING CAPACITY

CABINET

18 = 18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 BTU/HR [10.55 kW] 42 = 42,000 BTU/HR [12.31 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW]

A = FULL METAL JACKET

RHEEM VALUE SERIES

J = 208-230 SINGLE PHASE

Performance Data AHRI Standard Conditions Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.

Outdoor Unit 15PJL

Indoor Coil and/or Air Handler

Total Capacity BTU/H [kW]

AHRI Cooling Performance 80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Net Net Snd. Sens. Latent EER SEER Rate BTU/H BTU/H dB [kW] [kW]

Indoor CFM [L/s]

AHRI Heating Performance (70°F [21°C] Indoor) Outdoor Air Outdoor Air 47°F [8.5°C] DB/ 17°F [–8.5°C] DB/ DOE 43°F [6°C] WB 15°F [–9.5°C] WB Region DOE High Temp. DOE Low Temp. IV HSPF BTU/H BTU/H COP COP [kW] [kW]

Rev. 7/1/10

RHLL-HM2417 (RCSL-H*2417) ➀

18,500 [5.4]

13,400 [3.9]

5,100 [1.5]

12.50

15.00

76

600 [283]

17,700 [5.2]

3.68

10,800 [3.2]

2.38

8.50

RHBL-FR24T

19,600 [5.7]

14,900 [4.4]

4,700 [1.4]

12.50

15.00

76

600 [283]

16,500 [4.8]

3.48

9,500 [2.8]

2.04

8.20

RCFL-H*2414

18,200 [5.3]

13,100 [3.8]

5,100 [1.5]

11.50

13.50

76

600 [283]

18,200 [5.3]

3.42

11,300 [3.3]

2.24

7.70

RCFL-H*2417

18,200 [5.3]

13,100 [3.8]

5,100 [1.5]

11.00

13.50

76

600 [283]

18,200 [5.3]

3.42

11,300 [3.3]

2.24

7.70

RCFL-H*2417 (RGFD-06?MCK?)

18,400 [5.4]

13,350 [3.9]

5,050 [1.5]

12.50

15.00

76

600 [283]

17,800 [5.2]

3.64

10,900 [3.2]

2.36

8.20

RCFL-H*2417 (RGFD-07?MCK?)

18,400 [5.4]

13,350 [3.9]

5,050 [1.5]

12.50

15.00

76

600 [283]

17,800 [5.2]

3.64

10,900 [3.2]

2.36

8.20

RCFL-H*2417 (RGFE-06?MCK?)

18,500 [5.4]

13,400 [3.9]

5,100 [1.5]

12.50

15.00

76

575 [271]

17,700 [5.2]

3.68

10,800 [3.2]

2.38

8.20

RCFL-H*2417 (RGFE-07?MCK?)

18,400 [5.4]

13,300 [3.9]

5,100 [1.5]

12.50

15.00

76

600 [283]

17,700 [5.2]

3.68

10,800 [3.2]

2.38

8.20

RCFL-H*2417 (RGGD-06?MCK?)

18,500 [5.4]

13,400 [3.9]

5,100 [1.5]

12.50

15.00

76

600 [283]

17,700 [5.2]

3.68

10,800 [3.2]

2.38

8.20

RCFL-H*2417 (RGGD-07?MCK?)

18,400 [5.4]

13,300 [3.9]

5,100 [1.5]

12.50

15.00

76