Your Hayward Pro Series high-rate sand filter is a high performance, totally corrosion-proof filter that blends superior flow characteristics and features with ease of operation. It represents the very latest in high-rate sand filter technology. It is virtually foolproof in design and operation. When installed, operated and maintained according to instructions, your filter will produce clear, sparkling water with minimal attention and care.

HOW IT WORKS Your filter uses special filter sand to remove dirt particles from pool water. The filter sand is loaded into the filter tank and functions as the permanent dirt removing media. The pool water, which contains suspended dirt particles, is pumped through your piping system and is automatically directed by the patented filter control valve to the top of the filter tank. As the pool water is pumped through the filter sand, dirt particles are trapped by the sand bed, and filtered out. The cleaned pool water is returned from the bottom of the filter tank, through the control valve and back to the pool through the piping system. This entire sequence is continuous and automatic and provides for total recirculation of pool water through your filter and piping system. After a period of time, the accumulated dirt in the filter causes a resistance to flow, and the flow diminishes and the pressure gauge rises. This means it is time to clean (backwash) your filter. With the control valve in the backwash position, the water flow is automatically reversed through the filter so that is directed to the bottom of the tank, up through the sand, flushing the previously trapped dirt and debris out the waste line. Once the filter is backwashed (cleaned) of dirt, the control valve is manually positioned to Rinse, and then positioned to Filter to resume normal operation.

2. Assemble the Pump to the platform base. The adapters must now be installed to connect the pump/filter system. a. Apply Teflon pipe sealant tape or Permatex No. 2 sealant to straight adapter. Screw adapter into pump discharge port. (Do not overtighten.) b. Apply Teflon pipe sealant tape or Permatex No. 2 sealant to elbow adapter. Screw adapter securely into opening in control valve marked PUMP. (Do not overtighten.) 3. Loading sand media. Filter sand media is loaded through the top opening of the filter. a. Loosen flange clamp and remove Filter Control Valve (if previously installed). b. Cap internal pipe with sand shield to prevent sand from entering it. Be sure pipe is securely in place in bottom underdrain hub. c. We recommend filling tank approximately 1/2 way with water to provide a cushioning effect when the filter sand is poured in. This helps protect the underdrain laterals from excessive shock. (Be sure the winter drain cap is securely in place on drain pipe.)

39-1/2” (100 cm)

INSTALLATION Only simple tools (screwdriver and wrenches), plus pipe sealant for plastic adapters, are required to install and/or service filter. 1.

The filter system must be placed on level, very firm, ground. Position the filter so that the piping connections, control valve and winter drain are convenient and accessible for operation, service and winterizing.

16” (41 cm) 29-1/2” (75 cm)

SPECIFICATIONS EFFECTIVE FILTRATION AREA MODEL NUMBER

FT2

M2

S210T1580

2.2

0.21

DESIGN FLOW RATE*

GPM LPM 44

167

PRESSURE LOSS AT DESIGN FLOW RATE

MAXIMUM WORKING PRESSURE

PSI

BAR

PSI

BAR

INCH

MM

INCH

MM

FILTER SAND

LBS

KGS

2

0.14

50

3.45

18

457

18

457

0.45-0.55 mm

200

91

REQUIRED CLEARANCE SIDE

MEDIA REQUIRED

ABOVE

TYPE

AMOUNT

*Based on 20 GPM/ft.2 / 813.98 LPM/m2 (maximum allowable NSF rating).

PARTS S210T1580 Filter Systems

REF. NO.

a b

NOTE: The System Base has provisions for mounting optional timer and optional automatic chlorinator. See dealer for details.

PART NO.

DESCRIPTION

NO. REQ’D.

1

SP0714T

Multiport Valve

1

2

ECX27081

Pressure Gauge

1

3

GMX600F

Valve/Tank O-Ring

1

4

GMX600N

Flange Clamp (Valve-Tank)

1

5

SX202S

Sand Shield

1

6

SX180DA

Lateral Assembly with Cen