HANNA instruments HI9147-10 -

HANNA instruments HI9147-10 - - Dissolved Oxygen Meter for Aquaculture Owners Manuals, User Guides, Instructional Help Documents & Operating Information - user-manual-HANNA%20INSTRUMENTS-HI%209147-E.pdf

Report DMCA / Copyright

DOWNLOAD PDF

  • 283KB
  • 2 Pages
  • 595.276 x 841.89 pts (A4)
  • 19 Downloads
  • 195 Views

 

Citation

You can read the recommendations in the user guide, the technical guide or the installation guide for HANNA INSTRUMENTS HI 9147. You'll find the answers to all your questions on the HANNA INSTRUMENTS HI 9147 in the user manual (information, specifications, safety advice, size, accessories, etc.). Detailed instructions for use are in the User's Guide. User manual HANNA INSTRUMENTS HI 9147 User guide HANNA INSTRUMENTS HI 9147 Operating instructions HANNA INSTRUMENTS HI 9147 Instructions for use HANNA INSTRUMENTS HI 9147 Instruction manual HANNA INSTRUMENTS HI 9147

Your user manual HANNA INSTRUMENTS HI 9147

Manual abstract: O. probe (fixed) Liquid Crystal Display BL key, turn the backlight ON (as long as it is pressed) °C key, display temperature measurement % key, display O2 measurement in % of saturation % trimmer, for calibration adjustment SAL trimmer, for setting salinity compensation value SAL key, display setting of salinity factor (active only in mg/L measurement mode) 9) mg/L key, display O2 measurement in mg/L (ppm) 10) OFF key, turn the instrument OFF Note: To turn the instrument ON, press any of the measurement keys (°C, %, mg/L) 1) 2) 3) 4) 5) 6) 7) 8) ACCESSORIES HI 76409/4* Galvanic D.O. probe with builtin temperature sensor and 4 m cable HI 76409/10* Galvanic D.O. probe with built-in temperature sensor and 10 m cable HI 76409-0 Protective sleeve for HI 76409 probes series HI 76409A/P Membrane for HI 76409 probes series, 5 pcs. HI 7042S Electrolyte solution, 30 ml bottle HI 710015 Shockproof rubber boot, blue color HI 710016 Shockproof rubber boot, orange color HI 731326 Calibration screwdriver (20 pcs) HI 710040 Battery recharger * To be substituted by authorized technical personnel only Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. IST9147R2 05/05 PROBE PREPARATION All Hanna D.O. probes are shipped dry. To hydrate the probe and prepare it for use proceed as follows: 1. Remove the black & red plastic cap. This cap is used for shipping purposes only and can be thrown away. 2. Insert the supplied O-ring in the membrane (see figure). CALIBRATION Calibration is a very simple 1-point procedure, performed in air. Ensure the probe is ready for measurements, i.e. the membrane is filled with electrolyte (see "Probe Preparation" section for details). Switch the meter on, select the % mode and turn the % trimmer to display 100%. If the environmental relative humidity is lower than 30%, pour some deionized water (approx. 3 mm) in the white cap supplied with the membrane. Insert the probe in the cap and calibrate. Keep the probe in vertical position to avoid any contact of the membrane with the water. Note: For best accuracy, calibration should be performed on the measurement site, and the probe should be at the same temperature as the air. Note: After replacing the membrane or the electrolyte solution, wait a few minutes for the reading to stabilize. SALINITY COMPENSATION Oxygen measurements (mg/L range only) can be compensated for salinity factor and the correction value can be set by the user. Enter the mg/L mode by pressing the corresponding key. Keep the SAL button pressed while turning the SAL trimmer to display the desired salinity value (within the 0 to 51 g/L range). BATTERY RECHARGE & REPLACEMENT The instrument features a battery level control system: the "V" tag on the LCD lights up to advise the user that only a few hours of working life are left. The instrument is also provided with BEPS (Battery Error Preventing System), which turns the meter off if the battery level is too low to ensure reliable readings. The 9V battery provided with the instrument can be recharged using the optional HI 710040 battery recharger. Plug the recharger and the green LED will turn on, then put the meter on the recharger and the LED will turn to orange, to indicate that the battery is charging. ALTITUDE COMPENSATION When salinity compensation is not required (i.e. not salty water), the SAL trimmer can be used to set the altitude correction value.